The release of the European Union ERP tolerance directive

Time:2017/6/5Posted:Tianjin Huantong Detection Technology Co., Ltd.

In December 20, 2016, the European Union issued an ERP tolerance instruction using COMMISSION REGULATION (EU) 2016/2282. The directive came into effect on January 9, 2017.

Impact object:

(EC) No 1275/2008,(EC) No 107/2009,(EC) No 278/2009,(EC) No 640/2009,(EC) No 641/2009,(EC) No 642/2009,(EC) No 643/2009,(EU) No 1015/2010,(EU) No 1016/2010,(EU) No 327/2011,(EU) No 206/2012,(EU) No 547/2012,(EU) No 932/2012,(EU) No 617/2013,(EU) No 666/2013,(EU) No 813/2013,(EU) No 814/2013,(EU) No 66/2014,(EU) No 548/2014,(EU) No 1253/2014,(EU) 2015/1095,(EU) 2015/1185,(EU) 2015/1188,(EU) 2015/1189,以及(EU) 2016/2281

Affected products:

(EC) No 1275/2008 covering products, set-top box, external power supply, a motor, a circulator, television sets, household refrigeration appliances, household washing machine, household dishwasher, industrial fan, air conditioner, fan, water pump, comfortable household computer, dryers, vacuum cleaners, water heaters, space heater, lampblack machine, oven, stove, transformer, ventilation equipment, professional freezers, solid fuel in local space heater, local space heater, air heating / cooling products, high temperature chiller and fan coil.

primary coverage

Tolerance (verification, tolerances) in the ERP directive is only allowed in spot checks. Neither the manufacturer nor the importer applies this tolerance in the technical documentation;
The declared values in the technical documentation and the data sources used to calculate this value should not be superior to the measured values in the test report;
Declared value must comply with the ERP directive limit requirements, manufacturers and importers of other product information can not be superior to the declared value;
Market sampling, if the first sample in line with tolerance requirements are qualified, otherwise you need to check three samples of the same model, the average value of three samples meet the requirements of qualified, otherwise unqualified.
Suggestions
The affected ERP report shall update (EU) 2016/2282 information as soon as possible to comply with the regulatory requirements.
Data in the nameplate, energy efficiency label and technical documentation which does not conform to the test data shall be modified as soon as possible or by updating test data to meet the product information requirements.
Source: Intertek

Copyright © 2016 Tianjin Huantong Detection Technology Co., Ltd.
All Right Reserved
Hotline: 022-84819220 / Mr Meng:17702298445 / Mr Huang:18920860163
Fax: 022-84819220 / E-mail: huangxin002@tj-gts.com
Address: 8F, Building 2, Building 6, Ronghe Plaza, 168 West Fourth Road, Tianjin Free Trade Zone (Tianjin Economic Zone)